On this page
Quick answer
The VHome is a home ventilator from React Health’s VOCSN family. It uses two washable foam filters, an external bacterial filter and Ventec One-Circuits. It runs on wall power, two removable batteries and one internal battery. Your supplier chooses your parts.
React Health writes the name as V*Home. Its manual is the VOCSN Clinical and Technical Manual, which covers the V*Home setup. This guide explains the supplies. It does not cover settings. Your clinician and supplier decide those.
What makes the VHome different
- It’s part of the VOCSN family. The VHome is the VOCSN ventilator set up for ventilation, with oxygen from an outside low-pressure source. It has no built-in oxygen concentrator, cough, suction or nebulizer.
- Where to find the name. The setup name is printed on the back label. It also shows on the My VOCSN screen, along with the software version. The serial number is on the back label too.
- The front may say React Health. React Health says its ventilators will show “React Health” on the front panel instead of “VOCSN.” Older units may still say VOCSN.
- Ventec and React Health. Ventec Life Systems makes the VOCSN family and is part of React Health. You’ll see both names on parts and paperwork.
The parts, one by one
Patient air intake filter and fan filter
The VHome has two foam filters on the back. The patient air intake filter cleans the air you breathe. The fan filter cleans the air for the cooling fan. Both are washable and reusable.
The manual’s schedule for both:
- Look at them every day during use.
- Clean them every 2 weeks.
- Replace them every 6 months, or sooner if damaged.
Part numbers: patient air intake filter PRT-00977-000 and fan filter PRT-00978-000 (25-packs). Your supplier may give you a different schedule. Follow theirs.
Clogged filters can make the case abnormally warm. A clogged fan filter can also stop the batteries from charging.
Cleaning the foam filters
Make sure the person has backup ventilation if they need it. Then follow the manual’s steps in order:
- Power off and unplug the VHome.
- Remove the air and fan filters.
- Look them over for dirt or damage.
- Wash them in warm water with soap or a mild detergent.
- Rinse them well under running water, until no soap is left.
- Lay them on a clean surface and let them dry completely.
- Look them over again. Replace a damaged filter. If one still looks dirty, clean it again.
- Put the filters and the cover plate back, with the slats facing down. Check that the black o-ring around the fan filter cover grate is in place.
External bacterial filter
This filter is the first thing on the circuit connection port. It twist-locks onto the VHome and helps protect against germs passing between the machine and the circuit.
It is for one person only. The manual says to replace it between patients, when it’s dirty or damaged, or at least every 30 days. Part number: PRT-00850-000 (10-pack).
There is also an internal bacterial filter inside the device. A trained technician replaces it. It is not a home task.
Ventec One-Circuit
The manual says the VOCSN family is designed only for Ventec One-Circuits. Don’t use another brand’s patient circuit.
React Health’s VHome training checklist lists passive, valveless and mouthpiece circuits. Active circuits are for the V+Pro model.
| Circuit | What it’s for | Adult / pediatric 10-pack |
|---|---|---|
| Passive | A fixed-leak breathing-out port, for non-vented masks, trach or breathing tubes | PRT-00946-000 / PRT-01015-000 |
| Passive, Heated | The same, with a heated wire for use with a humidifier | PRT-00948-000 / PRT-01016-000 |
| Valveless | No breathing-out valve, for vented masks or a nasal cannula used for High Flow | PRT-00942-000 / PRT-00983-000 |
| Valveless, Heated | The same, with a heated wire | PRT-00943-000 / PRT-00985-000 |
| Mouthpiece | A mouthpiece circuit kit sold through Ventec | Ask your supplier |
One-Circuits are for one person only. Don’t clean or reuse them.
After any circuit change, the manual says to run a Pre-Use Test. Breathing support pauses during the test, so have backup ventilation ready if needed. Your supplier can show you how.
Don’t put lubricants on the VHome or the circuit. Don’t use anti-static or electrically conductive tubing.
Humidifier or HME
Ventec recommends the Fisher & Paykel HC550, the Fisher & Paykel MR850, or an equivalent humidifier.
- Use a heated-wire circuit with a humidifier, to manage condensation.
- Place the humidifier lower than the VHome and lower than the person.
- Don’t run a heated-wire circuit under blankets or near a heat source.
Without a humidifier, an HME (heat and moisture exchanger) goes between the breathing-out valve and the person. The manual notes that an HME works poorly with a vented mask.
Oxygen adapter
The O2 Low-Pressure Inlet Adapter (PRT-00981-000) connects an oxygen concentrator or liquid oxygen to the port on the back.
- Remove the adapter when it isn’t in use.
- Keep the oxygen source turned off while the VHome is off.
- The manual says to use a separate oxygen monitor with low-pressure oxygen.
Your clinician sets your oxygen. Don’t change it on your own.
Power adapter and three batteries
- AC Power Adapter (PRT-01333-000). A 10-foot cord plus an adapter with a threaded connector. Screw the connector clockwise to lock it. Check the cord for damage or fraying, and never use a damaged one.
- Two removable batteries (set PRT-00980-000). You can swap them while the VHome is running. To remove one, lift the blue tab and pull gently.
- One internal battery. It is only for power failures and battery swaps. Service staff replace it.
The batteries charge whenever the VHome is plugged in. The front light is orange while charging and green when full. The manual lists about 5 hours to charge each removable battery from empty, and up to 14 hours for all three. The Removable Battery Quick Charger (PRT-01003-000) charges each battery in about 3 hours.
How long do they last? With new batteries, the manual lists about 6 hours from the two removable batteries and about 2 hours from the internal battery. Real run time is often shorter. It depends on your settings and battery age.
If the batteries won’t be used for a while, the manual says to fully charge all three every 30 days, unless Battery Storage Mode is used.
Carry bag, stand and wheelchair cable
- Carry Bag (PRT-01143-000): the VHome works fully inside it, and you can reach the batteries.
- Roll Stand (PRT-00569-001): a wheeled stand. Keep the ventilator on a flat, stable surface, the roll stand or the carry bag, so it can’t fall.
- 24V Wheelchair Power Cable (PRT-01027-000): runs the VHome from a wheelchair battery. That can shorten the wheelchair’s range. The manual says to check that the wheelchair’s power matches the VHome’s limits first, so ask your supplier before you use it.
For outages and trips, see our home ventilator power outage and travel plan.
What your supplier and clinician decide
- Which circuit and filters you use.
- Your settings, oxygen and alarms. The manual says patients and caregivers shouldn’t change the setup without a clinician’s direction.
- How often parts get changed.
- Repairs and servicing, including the internal battery and internal filter.
Don’t change your machine’s settings on your own. Ask your supplier.
Questions to ask your supplier
- Which One-Circuit do I use, and what is the part number?
- How often should I change the circuit and bacterial filter?
- Can you show me how to run the Pre-Use Test?
- Do my removable batteries still hold a full charge?
- Who do I call at night or on weekends?
Keep track of it
DuradMedical members can use Supply Reminders. You add your machine and mask, enter when you last replaced each part (using your supplier’s schedule), and we email you before each part is due. Then you can order it here, or from your own supplier.
When to call your supplier
Call the company that supplied your ventilator if:
- The Maintenance Due alert shows. React Health’s checklist says to contact your equipment supplier for service.
- The VHome stops working or acts in a way you don’t expect. The manual says to use backup ventilation right away and contact service.
- The VHome was dropped, or the case is cracked. React Health says a dropped unit needs a check (the Checkout Procedure) before it’s used again, so use your backup until your supplier checks it.
- A battery looks warped, discolored or leaking, or won’t charge. The manual says not to use or charge a damaged battery.
- You’re not sure which part fits.
FDA early alert. FDA has posted an early alert about a cable issue in VOCSN-family ventilators, including some V*Home units. If your ventilator restarts on its own again and again, use backup ventilation and contact React Health or your supplier. Read FDA’s notice in the sources below.
The manual also lists Ventec’s support line: 1-844-MY-VOCSN.
Parts for this guide
Check the label on your current part, or your user guide, before you order. Confirm fit with your supplier before ordering.
-
Ventilator supplies Ventec
Ventec VOCSN One-Circuit, Adult Passive
$56.99Member price $51.99 How membership works Add to cart -
Ventilator supplies Fisher & Paykel
Fisher & Paykel MR290 Humidification Chamber
$42.99Member price $37.99 How membership works Add to cart
Sources
- Ventec Life Systems (React Health). VOCSN Series Ventilator Portfolio Clinical and Technical Manual (LBL-00001-001, Rev AE). https://www.reacthealth.com/uploads/userfiles/files/documents/LBL-00001-001-AE%20vocsn_clinical_technical_manual_software_v4-06%20-%205-06%20AE.pdf
- React Health. V*Home & V+Pro Caregiver and Patient Training Checklist (LBL-00542-000, Rev A). https://www.reacthealth.com/uploads/userfiles/files/documents/LBL-00542-000%2C%20VHome%20%26%20V%2BPro%20Caregiver%20Training%20Checklist%2C%20Rev%20A.pdf
- Ventec Life Systems / React Health. Buyers Guide (MKT-00004, Rev K). https://www.reacthealth.com/uploads/userfiles/files/documents/MKT-00004%2C%20Buyers%20Guide%20without%20Pricing%2C%20Rev%20K%5B68857%5D%281%29.pdf
- React Health. Home page (front-panel name note). https://www.reacthealth.com/
- U.S. Food and Drug Administration. Early Alert: Ventilator Issue from React Health. https://www.fda.gov/medical-devices/medical-device-recalls-and-early-alerts/early-alert-ventilator-issue-react-health
- Ventec Life Systems. VOCSN Home Caregiver and Patient Guide (LBL-00008-000, Rev D). https://www.venteclife.com/assets/Resources/Home-Caregiver-and-Patient-Guide.pdf